Page 1 - R217M40 Rev.D

MAXO2®+A /AE USER’S GUIDE & OPERATING INSTRUCTIONSBATCALMAXO2®+AMAXO2®+AER217M40 Rev.DmedicalManual.RevD.qxd 9/9/04 4:18 PM Page 1

Page 2 - DECLARATION OF CONFORMITY

9.2 Standard Replacement PartsPart Number ItemR125P02-011 MAX-250+ Oxygen SensorR125P03-002 MAX-250E Oxygen SensorR115P85 MAX-250ESF Oxygen SensorR217

Page 3 - Classification

14MANUFACTURED BY MAXTEC, INC.10.0 WARRANTYThe MAXO2®+Analyzer is designed for medical oxygen delivery equipment and systems. Under normaloperating co

Page 4 - TABLE OF CONTENTS

17WWW.MAXTECINC.COM16MANUFACTURED BY MAXTEC, INC.medicalManual.RevD.qxd 9/9/04 4:18 PM Page 22

Page 5 - FIGURE 1

medicalManual.RevD.qxd 9/9/04 4:18 PM Page 24

Page 6 - + Oxygen Analyzer

PREFACEThis manual describes the function, operation and maintenance of the MAXO2®+hand-held oxygen analyzer. A member of Maxtec®'s MAXO2®analyze

Page 7

ClassificationProtection against electric shock: Internally powered equipment.Protection against water: IPX1Mode of Operation: ContinuousSterilizat

Page 8 - 5.0 CHANGING THE BATTERIES

1.0 SYSTEM OVERVIEW1.1 Base Unit DescriptionThe MAXO2®+analyzer provides unparalleled performance and reliability dueto an advanced design that includ

Page 9

1.4 MAX-250+ Oxygen Sensor The MAX-250+ oxygen sensor offers stability and extra life.The MAX-250+ is a galvanic, partial pressure sensor that is spec

Page 10 - A Model AE Model

• If you are unsure about the displayed O2percentage. (see Factors influencing accurate readings.) A simple calibration may be made with the sensor op

Page 11 - 10.0 WARRANTY

• Calibrate the MAXO2®+at the same pressure as the sample gas.• If sample gases flow through tubing, use the same apparatus and flow rateswhen calibra

Page 12 - MANUFACTURED BY MAXTEC, INC

FIGURE 4Lock LeverCarefully, bring the two halves of the case together while positioning the wires sothey are not pinched between the two case halves.

Page 13

exhaled breath or secretions, unless you intend to dispose of the sensor, flow diverterand tee adapter after use.• Clean the sensor with a cloth moist